Eaton Wiring Devices BRP12B100 100 Amp Main Breaker Residential Load Center
Rapid Ship
Key Features
- Knockout locations for additional access
- Optimized knockouts easier to remove
- Smooth case edges provides a more professional look and fee
- Top or bottom feed straight-in wiring saves labor and material
- One panel for either top or bottom applications
- 2/0 lug easily removable and can be installed in any location on the neutral bar
- Compact design for easier wiring improved wireway access
- Provides a clean gutter space
Main breaker loadcenter - br type - residential - top feed surface/flush mount indoor - nema 1 - g60 b2 box - 14-5/16 inches width by 18-3/4 inches height by 3-7/8 inches depth - 100 amp rating Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 12 ( 1 inch ) spaces, 20 poles, 120/240 volt. Main breaker type BR at 10,000 AIR. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus. When bonded, unused ne utral connections may be used for equipment ground protectors in service entrance application. #4 - 1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with N EC 240-81 requirements because it operates horizontally. 14- 5/16 inches x 18- 3/4 inches x 3- 7/8 inches. UL Listed file E52977.
Galvanized steel enclosure. Single phase, 3-wire, insulated/bondable split neutral, 12 (1 in) spaces, 20 poles, 120/240 V. Main breaker type BR at 10,000 AIR. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #4 - 1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 deg for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. 14-5/16 in x 18-3/4 in x 3-7/8 in. UL listed file E52977. Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 12 ( 1 inch ) spaces, 20 poles, 120/240 volt. Main breaker type BR at 10,000 AIR. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus. When bonded, unused ne utral connections may be used for equipment ground protectors in service entrance application. #4 - 1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with N EC 240-81 requirements because it operates horizontally. 14-5/16" x 18-3/4" x 3-7/8". UL Listed file E52977.