Cutler Hammer BRP120AF 1 Pole 20A Arc Fault Breaker

SKU
KJDA-9139
Our Price
$71.39
List Price
$80.69
You Save
$9.30 (12%)
$71.39 $80.69

Rapid Ship

Leaves our warehouse in 1 to 3 business days

Arc fault circuit breakers plug-on - single pole combination br- 1 inch wide amp rating=20 Plug-on combination type arc fault circuit breakers, 10,000 amperes interrupting capacity. Combination type arc fault circuit interrupter includes all of the protection offered by the branch feeder AFCI (mitigation of parallel arcing faults in the complet e circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. Parallel arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load.

Plug-on combination type arc fault circuit breakers, 10,000 A interrupting capacity. Combination type arc fault circuit interrupter includes all of the protection offered by the branch feeder AFCI (mitigation of parallel arcing faults in the complete circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 A with associated mitigation of fire hazards in the cords connected to the outlets. Parallel arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load. Plug-on combination type arc fault circuit breakers, 10,000 amperes interrupting capacity. Combination type arc fault circuit interrupter includes all of the protection offered by the branch feeder AFCI (mitigation of parallel arcing faults in the complet e circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. Parallel arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load.

Additional Information

SKU
KJDA-9139
Part Number
BRP120AF
UPC
786689041021
Shipping Weight
9.20 ounces
Domestic Shipping
Item can be shipped anywhere in the US including APO/FPO addresses and territories.
International Shipping
Item can be shipped anywhere in Canada including the territories.

About Us | Accessibility | Privacy & Security Policy | Terms of Sale | Terms & Conditions of Use

Copyright © 2002-2023 Hardware and Tools Corp. All Rights Reserved.